Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Aust Endod J ; 2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37876340

RESUMO

This study evaluated the impact of long-term storage conditions (medium and time) on the development of experimental dentinal microcracks through micro-computed tomography. Sixty freshly extracted premolars were stored in formalin, water, or dry conditions (n = 20) and scanned after 72 h, 30 days, 6 months and 3 years of extraction. The effect of the storage medium and time on the occurrence of dentinal defects was statistically evaluated. A total of 211 000 images were screened revealing the existence of 11 519 slices with dentinal defects. Dry conditions significantly contributed to the development of new defects in all time points. During the 3-year follow-up period, no new defects were detected in the teeth that were stored in water and, in a single tooth, in the formalin group, after 6 months of storage.

2.
J Endod ; 49(12): 1722-1732, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37717910

RESUMO

INTRODUCTION: This study aimed to assess the canal transportation with 6 preparation systems. METHODS: Sixty curved mesial roots of mandibular molars were scanned, and their root canals (n = 20 per group) were prepared with XP-endo Shaper, BioRace, ProTaper Next, Twisted File Adaptive, Reciproc, or Reciproc Blue systems. After preparation, a new scan was conducted, and transportation was determined by comparing the geometric center of the canal in 13,542 cross-sectional slices. The transport direction frequencies were recorded, and linear transport were compared using a Univariate GLM model and Tukey honestly significant difference tests (α = 5 %). RESULTS: Transportation was affected by the preparation system and root third (P < .05), with no significant effect observed for the root canal (P > .05). The Twisted File Adaptive had the highest transport (P < .05), and the lowest transports were observed with XP-endo Shaper, ProTaper Next, and BioRace (P < .05). Reciproc Blue and Reciproc showed intermediate results (P < .05). The apical and coronal third exhibited the lowest and highest transportation, respectively (P < .05). A significant interaction was observed between the preparation system and root third (P < .05). In the coronal third, transportation was mostly toward the disto-inside direction, whereas in the middle and apical thirds, transportation was predominantly toward the mesio-outside direction. CONCLUSIONS: XP-endo Shaper had the lowest mean linear transportation followed by the ProTaper Next, BioRace, Reciproc Blue, and Reciproc systems. The Twisted File Adaptive system had the worst performance. The direction of transportation was generally toward the inner aspect of the canal at the coronal third and toward the outer aspect of the curve at the middle and apical thirds.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Preparo de Canal Radicular/métodos , Microtomografia por Raio-X/métodos , Estudos Transversais , Tratamento do Canal Radicular , Desenho de Equipamento
3.
J Endod ; 49(5): 487-495, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36848949

RESUMO

INTRODUCTION: This study aimed to compare the in vivo accuracy and precision of 3 electronic apex locators (EALs) in determining the position of the major foramen using micro-computed tomographic (micro-CT) technology. METHODS: After access preparation of 23 necrotic or vital teeth from 5 patients, canals were negotiated, and hand files were used to determine the position of the foramen with 3 EALs: Propex Pixi (Dentsply Maillefer, Ballaigues, Switzerland), Woodpex III (Woodpecker Medical Instrument Co, Guilin, China), and Root ZX II (J Morita, Tokyo, Japan). After fixing the silicon stop to the file, teeth were extracted and scanned in a micro-CT device with and without the instrument inserted into the canal. Data sets were coregistered, and the accuracy and precision of the EALs were determined at a tolerance level of ±0.5 mm by measuring the distance from the tip of the instruments to a tangential line crossing the margins of the foramen. Statistical comparisons were performed using Friedman with post hoc related samples sign and Spearman tests (α = 5%). RESULTS: A significant difference was detected comparing the accuracy of Root ZX II (100%), Woodpex III (86.96%), and Propex Pixi (52.17%) (P < .05). There was a lack of significance in the relationship between the pulp status and the accuracy of the tested EALs (P > .05). Propex Pixi was significantly less precise than Root ZX II (P < .05), whereas no difference was found between Woodpex III and Root ZX II or Propex Pixi (P > .05). CONCLUSIONS: EALs presented similar precision, but Woodpex III and Root ZX II showed better accuracy to determine the position of the apical major foramen than Propex Pixi.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Humanos , Cavidade Pulpar/diagnóstico por imagem , Odontometria , Ápice Dentário/diagnóstico por imagem , Eletrônica
4.
J Endod ; 48(9): 1152-1160, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35780927

RESUMO

INTRODUCTION: This study aimed to compare the in vivo accuracy of Wirele-X and RootZX II electronic apex locators (EALs) in determining the position of the major foramen using micro-computed tomography (micro-CT) as the analytical tool. METHODS: Eleven vital teeth planned for extraction from 5 patients were used. After conventional access cavity preparation, root canals were flared and negotiated up to the apical third with sizes 08 and 10 K-files followed by irrigation with 2.5% NaOCl. K-type files were used to determine the working length of the selected canals using Root ZX II and Wirele-X apex locators until their numeric displays read "0.0." After fixing the silicon stop to the file, teeth were extracted and imaged in a micro-CT device using a double-scan protocol. Image stacks, with and without the file in the root canal, were then co-registered and the measurement error calculated as the absolute difference between the tip of the file and the major foramen. Positive and negative values were recorded when the file tip was detected beyond or short of the major foramen, respectively. Accuracy was determined on stable measurements within ± 0.5 mm when the file tip did not extend beyond the major foramen. The χ2 test was applied to compare the ability of the EALs to detect the position of the major foramen, and the t test for dependent variables was used to verify differences in the 2 measurements obtained in each tooth. Significance level was set at 5%. RESULTS: Within a tolerance level of ± 0.5 mm, no significant differences were observed between the tested EALs regarding the absolute distance values (P = .82) or in their ability to detect the position of the major foramen (χ2 = 0.2588; P = .6109). The accuracy of the Root ZX II and the Wirele-X apex locators within ± 0.5 mm were 81.8% and 90.9%, respectively. CONCLUSIONS: Root ZX II and Wirele-X performed similarly regarding the in vivo detection of the major foramen. Using strict criteria, the accuracy of the Root ZX II and the Wirele-X apex locators were 81.8% and 90.9%, respectively.


Assuntos
Preparo de Canal Radicular , Ápice Dentário , Cavidade Pulpar/diagnóstico por imagem , Eletrônica , Humanos , Odontometria , Ápice Dentário/diagnóstico por imagem , Microtomografia por Raio-X
5.
Int Endod J ; 55 Suppl 2: 384-445, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35226760

RESUMO

Canal filling materials and techniques have been one of the most studied topics in Endodontics. A simple search using the mesh term "root canal filling" in PubMed revealed more than 11 000 articles, an impressive number that is much higher than "root canal disinfection" (5544 articles) or even the popular "root canal preparation" (8527 articles). The overriding importance attributed to root filling procedures is not merely intuitive. It derived from the appealing relevance given by the appearance of the white lines in common radiographs grounded on retrospective clinical data that had identified the quality of a root filling as one of the major causes of treatment failure (lack of healing). Since the publication of the Washington study, impressive efforts have been made for the release of new materials and techniques, as well as, for the development of a plethora of laboratory methods to assess the quality of root filling procedures. This narrative review aims to address and discuss the most relevant laboratory methods to assess the root canal filling. As filling quality improvements have not translated into higher success rates, as reported in longitudinal clinical studies, more than to deliver a simple methodology-based review, this paper aims to present an in-depth critical view on the assessment of laboratory methods used to study the filling materials and techniques. Recent data indicate that the long-term dimensional stability/degradation over time of endodontic sealers plays a central role in the treatment outcome. In this context, laboratory methods should be developed focusing on predicting, at least to some degree, the long-term clinical behaviour of root canal fillings, rather than simply ranking different materials or techniques.


Assuntos
Cavidade Pulpar , Materiais Restauradores do Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Modelos Teóricos , Estudos Retrospectivos , Materiais Restauradores do Canal Radicular/uso terapêutico , Obturação do Canal Radicular/métodos , Preparo de Canal Radicular/métodos
6.
Int Endod J ; 55 Suppl 3: 531-587, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35100441

RESUMO

In the last decades, the move of medicine towards minimally invasive treatments is notorious and scientifically grounded. As dentistry naturally follows in its footsteps, minimal access preparation have also becume a trend topic in the endodontic field. This procedure aims to maximize preservation of dentine tissue backed up by the idea that this is an effective way to reduce the incidence of post-treatment tooth fracture. However, with the assessment of the body of evidence on this topic, it is possible to observe some key points (a) the demand for nomenclature standardization, (b) the requirement of specific tools such as ultra-flexible instruments, visual magnification, superior illumination, and three-dimensional imaging technology, (c) minimally invasive treatment does not seem to affect orifice location and mechanical preparation when using adequate armamentarium, but it (d) may impair adequate canal cleaning, disinfection and filling procedures, and also (e) it displays contradictory results regarding the ability to increase the tooth strengthen compared to the traditional access cavity. In spite of that, it is undeniable that methodological flaws of some benchtop studies using extracted teeth may be responsible for the conflicting data, thus triggering the need for more sophisticated devices/facilities and specifically designed research in an attempt to make clear the role of the access size/design on long-term teeth survival. Moreover, it is inevitable that a clinical approach such as minimal endodontic access cavities that demands complex tools and skilled and experienced operators bring to the fore doubts on its educational impact mainly when confronted with the conflicting scientific output, ultimately provoking a cost-benefit analysis of its implementation as a routine technique. In addition, this review discusses the ongoing scientific and clinical status of minimally invasive access cavities aiming to input an in-depth and unbiased view over the rationale behind them, uncovering not only the related conceptual and scientific flaws but also outlining future directions for research and clinical practices. The conclusions attempt to skip from passionate disputes highlighting the current body of evidence as weak and incomplete to guide decision making, demanding the development of a close-to-in situ laboratory model or a large and well-controlled clinical trial to solve this matter.


Assuntos
Cárie Dentária , Fraturas dos Dentes , Cavidade Pulpar , Desinfecção , Humanos , Preparo de Canal Radicular
7.
Int Endod J ; 55 Suppl 1: 178-226, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34743355

RESUMO

The purpose of this narrative review was to discuss the scientific milestones that led to the current understanding of the root dentinal microcrack phenomenon based on the interplay between the usage of micro-computed tomography (micro-CT) as an analytical tool alongside a close-to-mouth experimental model. In 2009, reports on the development of dentinal microcracks in extracted teeth after root canal preparation triggered an awareness of the potential for vertical root fractures (VRFs) of endodontically treated teeth could be developed from defects created by the mechanical stress of nickel-titanium preparation systems on dentine. This assumption was taken for granted, even though no cause-effect relationship had been scientifically demonstrated. Since then, several studies using the sectioning method with extracted teeth have been published and the large discrepancy amongst their outcomes soon become evident. Moreover, the high frequency of reported dentinal microcracks largely contrasted with the clinical incidence of VRFs, raising doubts on their methodological reliability. Using micro-CT technology, it was demonstrated by several studies that, in extracted teeth, dentinal defects already existed before the endodontic procedures, indicating that the initial reports framed a non-existing cause-effect relationship between canal preparation and dentinal microcracks. Although these new findings contributed to a better comprehension of this phenomenon, the misconception that microcracks were the starting point for VRFs was only surpassed with a new in situ approach using fresh cadavers. Surprisingly, microcracks were not identified in sound teeth. As a conclusion, dentinal microcracks in extracted teeth can be considered a non-natural occurrence observed only in a laboratory set-up as a consequence of dehydration and storage conditions. Thus, dentinal microcracks shall not be considered as the starting point for VRFs as they do not manifest in non-extracted teeth. Identifying dentinal microcracks as a laboratory phenomenon highlights the impact of recent scientific developments to disclaim the clinical relevance of laboratory-obtained outcomes.


Assuntos
Dentina , Preparo de Canal Radicular , Modelos Teóricos , Reprodutibilidade dos Testes , Microtomografia por Raio-X
8.
Restor Dent Endod ; 46(2): e28, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34123764

RESUMO

OBJECTIVES: This study evaluated the effect of repeated uses and autoclaving in the instrumented area, fracture resistance, and time of instrumentation of thermally treated nickel-titanium reciprocating systems. MATERIALS AND METHODS: Two hundred simulated canals were instrumented using Reciproc Blue and WaveOne Gold. Each file was used up to 10 times or until fracture. The instrumented area was measured in pre- and post-operative images, using ImageJ software. Kaplan-Meier survival analysis evaluated the number of uses of instruments before fracture. Instrumented area and time of instrumentation were analyzed by Mann-Whitney U test and Kruskal-Wallis. Correlations among the number of uses and instrumented area were measured. The level of statistical significance was set at p < 0.05. RESULTS: Reciproc Blue presented a higher estimated number of uses in comparison with WaveOne Gold (p = 0.026), but autoclaving did not affect the resistance to fracture of instruments (p > 0.05). The instrumented area was different among the evaluated groups (p = 0.039), and the instrumented area along the uses of both tested instruments was reduced. With the time of instrumentation, there was also a significant difference among the evaluated groups; the groups without sterilization cycles were faster, in comparison to those submitted to autoclaving (p = 0.010). CONCLUSIONS: Reciproc Blue was more resistant than WaveOne Gold, suffering later fracture. Additionally, the sterilization cycles did not influence the estimated number of uses of thermally treated reciprocating instruments, but the instrumented area of root canals was reduced along with the repeated uses of both instruments.

9.
Int Endod J ; 54(9): 1647-1652, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33932037

RESUMO

AIM: To assess the impact of mechanical overinstrumentation of root canals in extracted teeth on the development of dentinal microcracks in the apical portion of the root by means of micro-computed tomographic (micro-CT) analysis. Root canal preparation short of the canal terminus and at the apical foramen (AF) were used as controls. METHODOLOGY: Twenty 2-rooted maxillary premolars with two canals were selected, scanned in a micro-CT device and the root canals prepared sequentially using Reciproc M-Wire R25 instruments to working lengths: 1 mm short of the AF (AF - 1 mm), at the AF (AF), and overinstrumentation (AF + 1 mm). A micro-CT scan of each specimen was performed after each time point. After reconstruction and co-registration procedures, the images were screened from the cementoenamel junction to the apex (n = 55 352) to identify the presence of dentinal microcracks in the apical third of the root. RESULTS: After the analyses of 55 352 slices, dentinal microcracks were visualized in 12.45% of the images (6892 slices), with 5.73% (3174 slices) in the cervical, 3.57% (1976 slices) in the middle and 3.15% (1740 slices) in the apical third. All dentinal microcracks observed at all time points (AF - 1 mm, AF and AF + 1 mm) were already present in the corresponding images before canal instrumentation. Therefore, no new microcracks were detected, regardless of the working length used for canal instrumentation. CONCLUSION: Reciprocating root canal preparation either short, at or beyond the AF (overinstrumentation) did not create dentinal microcracks in the roots of extracted 2-rooted maxillary premolars.


Assuntos
Preparo de Canal Radicular , Ápice Dentário , Cavidade Pulpar , Humanos , Ápice Dentário/diagnóstico por imagem , Colo do Dente , Extração Dentária , Microtomografia por Raio-X
10.
J Endod ; 47(1): 100-104, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33045262

RESUMO

INTRODUCTION: This study assessed the number of mesial and distal canals of mandibular molars in which the R-Pilot pathfinding reciprocating instrument reached the working length (WL) during macro glide path procedure. Fracture and deformation rates were also evaluated. METHODS: One hundred fifty-six root canals of 52 teeth were scouted to the length of the apical foramen. Then the R-Pilot instrument was positioned at the canal orifice and activated. The instrument was moved by using a pecking motion and light apical pressure. This procedure was repeated in an attempt to reach the WL. The type of fracture and/or instrument deformation was assessed by scanning electron microscopy, whereas the roots with fractured instruments were scanned through micro-computed tomography. The percentage frequency distribution of fractures, deformations, and root canals in which the R-Pilot reached the WL were recorded and statistically compared by using the Pearson's χ2 test with α = 5%. RESULTS: R-Pilot instruments reached the WL in 139 root canals (89.10%), and χ2 test showed a significant difference between the observed frequencies and the expected frequencies (χ2 = 95.41, P = .000). The observed frequencies of fractures (2.56%) and deformations (1.92%) were also significantly lower than the expected (fracture: χ2 = 140.41, P = .000; deformation: χ2 = 144.23, P = .000). Fractures occurred mostly at the apical and curved parts of the root canals. CONCLUSIONS: R-Pilot reached the WL in 89.10% of the root canals of mandibular molars with fracture and deformation rates of 2.56% and 1.92%, respectively.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Ápice Dentário , Microtomografia por Raio-X
11.
Clin Oral Investig ; 25(6): 3641-3649, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33236240

RESUMO

OBJECTIVES: This study evaluated the danger zone (DZ) in mesial roots of mandibular molars and the correlation between anatomical references of the DZ and some anatomical landmarks including tooth/root length, depth of mesial and distal grooves, and inter-canal orifices distance. MATERIAL AND METHODS: Twenty-eight mesial roots of mandibular molars with 2 independent canals were scanned and divided into 2 groups according to root length. The anatomical landmarks were correlated (Pearson or Spearman coefficients) with root level, thickness, and position of the DZ and also compared (independent samples t or Mann-Whitney tests) between the 2 groups at α = 5%. RESULTS: No statistical difference was observed between groups regarding DZ parameters and depth of mesial and distal grooves (P > 0.05). Orifice distance in group 2 (4.49 ± 0.75 mm) was significantly greater than group 1 (3.76 ± 0.89 mm) (P < 0.05). Significant correlations (P < 0.05) were found between (i) DZ level and root/tooth length (r = 0.54 and 0.49, respectively), (ii) DZ thickness and distal groove depth (r = - 0.45), and orifice distance (r = 0.38), and (iii) DZ position and depth of mesial (r = 0.39) and distal (r = 0.40) grooves. Other variables such as root length and distal groove depth (r = 0.28), and orifice distance and mesial groove depth (r = 0.36) were also correlated (P < 0.05). CONCLUSIONS: The length of tooth/root, the distance of canal orifices, and the depth of mesial/distal grooves of mesial roots of mandibular molars might be predictive factors for the root level, position, and thickness of the DZ. CLINICAL RELEVANCE: The length, distance of mesial canal orifices, and the depth of mesial and distal grooves of the mesial roots of mandibular molars might be moderate predictive factors for the root level, position, and thickness of the DZ.


Assuntos
Mandíbula , Raiz Dentária , Cavidade Pulpar/diagnóstico por imagem , Mandíbula/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem
12.
J Endod ; 45(9): 1135-1141, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31350048

RESUMO

INTRODUCTION: The purpose of this study was to evaluate the ability of the XP-endo Shaper instrument (FKG Dentaire, La Chaux-de-Fonds, Switzerland) during the removal of root fillings from oval-shaped canals. M-Wire Reciproc and Reciproc Blue systems (VDW, Munich, Germany) were used as reference instruments for comparison, and micro-computed technology was used as an analytical tool. METHODS: Thirty mandibular incisors with oval-shaped canals were matched based on similar anatomic features of the canal (eg, volume, aspect ratio, and 3-dimensional configuration) after scanning procedures. The canals were prepared with M-Wire Reciproc R25 instruments and filled with gutta-percha and AH Plus sealer (Dentsply DeTrey, Konstanz, Germany) using the continuous wave of condensation technique. Then, the sample was allocated into 3 experimental groups (n = 10) according to the retreatment protocol used: M-Wire Reciproc, Reciproc Blue, and XP-endo Shaper. M-Wire Reciproc R25, Reciproc Blue R25, and XP-endo Shaper instruments were used to remove the root fillings. Apical enlargement was performed with M-Wire Reciproc R40, Reciproc Blue R40, and BioRace BR5 (FKG Dentaire) instruments. Each sample was scanned after each endodontic procedure. The volume of remaining root filling material was quantified before and after apical enlargement. The percentage volumes of root filling reduction in relation to the instrumented canals at both time points (before and after apical enlargement) were calculated and considered for statistical analysis. Data were analyzed statistically with a significance level of 5%. RESULTS: Reciproc Blue presented significantly lower removal of filling material compared with the XP-endo Shaper (Tukey test, P < .05). No difference was detected either between M-Wire Reciproc and Reciproc Blue (Tukey test, P > .05) or M-Wire Reciproc and XP-endo Shaper (Tukey, P > .05). The increase of apical enlargement significantly improved the removal of root fillings from the root canals (P < .05); this effect was similar for all systems (time point × file system, P > .05). CONCLUSIONS: The XP-endo Shaper instrument showed a higher percentage of root filling removal, but no differences were observed comparing M-Wire Reciproc with the XP-endo Shaper or Reciproc Blue. The increase of apical enlargement improved the removal of root fillings in all groups. None of them was able to render root canals completely free from root fillings.


Assuntos
Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular , Instrumentos Odontológicos , Cavidade Pulpar , Alemanha , Guta-Percha , Humanos , Retratamento , Preparo de Canal Radicular , Microtomografia por Raio-X
13.
J Endod ; 45(2): 194-198, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30711177

RESUMO

INTRODUCTION: This study assessed the frequency in which Reciproc Blue R25 instruments (VDW, Munich, Germany) reached the full working length (WL) of mandibular molar canals without a glide path. The influence of the type of electric motor (ie, conventional corded or cordless) on the instrument's performance was also assessed. METHODS: One hundred mandibular molars with slight to moderate root canals were selected and randomly assigned into 1 of 2 experimental groups according to the type of electric motor used: conventional corded (VDW Silver, VDW) or cordless motors (VDW.CONNECT Drive, VDW). Therefore, 50 molars and 154 root canals were selected for each motor. Reciproc Blue R25 instruments were used until reaching two thirds of the estimated WL. Then, a size 10 K-file was passively inserted to determine the full WL. No active instrumentation movement was performed with a size 10 K-file. Independently, whether a size 10 K-file reached the apex or not, Reciproc Blue R25 instruments were used to complete canal preparation. When the Reciproc Blue R25 instrument was able to reach the full WL, the case was classified as "reaching the full working length" (RFWL). If the instrument was not able to reach the full WL, the case was classified as "not reaching the full working length" (NRFWL). The chi-square test of goodness of fit was used to verify whether the observed frequencies of RFWL and NRFWL adhered to the expected ones. A 5% cutoff level of significance was considered for statistical assumptions. RESULTS: Reciproc Blue R25 instruments were able to reach the full WL in 304 root canals (98.70%). The chi-square test revealed the observed frequencies of RFWL and NRFWL to be significantly different from the expected frequencies (χ2 = 292,208, P = .000). The frequency of RFWL and NRFWL was exactly the same for both types of electric motors. No instrument fractured, and a single file deformed. In 50 of 308 root canals, a size 10 K-file was unable to passively reach the full WL. From these 50 canals, Reciproc Blue R25 instruments were able to reach the full WL in 47 of them. CONCLUSIONS: Reciproc Blue R25 instruments were able to reach the full WL in a high frequency of cases. The type of electric motor used did not interfere in the frequency of RFWL cases. No instrument fractured, and a single file deformed.


Assuntos
Instrumentos Odontológicos , Desenho de Equipamento , Preparo de Canal Radicular/instrumentação , Fontes de Energia Elétrica , Humanos , Mandíbula , Dente Molar
14.
Clin Oral Investig ; 23(7): 3087-3093, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30417226

RESUMO

OBJECTIVE: To compare the effectiveness of the XP-endo Finisher instrument and passive ultrasonic irrigation (PUI) as final irrigation protocols on the removal of accumulated hard-tissue debris (AHTD) from oval-shaped canals using micro-computed tomographic (micro-CT) analysis. METHODS: Twenty mandibular incisors were anatomically pair-matched based on similar morphological dimensions (length, volume, aspect ratio, and configuration) through micro-CT analysis, prepared with Reciproc R25 instrument, scanned again, and assigned to one of the two experimental groups (n = 10), according to the final irrigation protocol: XP-endo Finisher and PUI. After the final irrigation protocols, the specimens were rescanned and the registered datasets were examined to quantify the amount of AHTD. Data were statistically analyzed using Student's t test with a significance level of 5%. RESULTS: The final irrigation protocols were highly similar in terms of volumetric percentage reduction of AHTD (P = 1.000). CONCLUSIONS: XP-endo Finisher and PUI showed the same effectiveness on the removal of AHTD. None of the tested final irrigation protocols completely removed the AHTD from oval-shaped root canals. CLINICAL RELEVANCE: AHTD may be considered clinically relevant because it could harbor bacterial contents away from the disinfection procedures. Both final irrigation protocols were effective on the removal of AHTD.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Ultrassom , Humanos , Incisivo , Irrigantes do Canal Radicular , Irrigação Terapêutica , Microtomografia por Raio-X
15.
Aust Endod J ; 44(3): 260-266, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28940891

RESUMO

This study assessed the percentage of untouched canal areas and the amount of debris accumulation after canal preparation with ProTaper Next (PTN) and Twisted File Adaptive (TFA) systems using micro-computed tomographic (micro-CT) imaging. Twenty isthmus-containing mesial roots of mandibular molars were anatomically matched through micro-CT evaluation and randomly assigned to one of the two experimental groups (n = 10), according to the system used for canal preparation: PTN (X1 and X2 files using rotary motion) and TFA (SM1 and SM2 files using adaptive motion). After canal preparation up to ISO size 25, the specimens were then scanned and the matched images of the mesial canals, before and after preparation, were examined from the furcation level to the apex to quantify the untouched surface canal areas and to evaluate the amount of accumulated debris. An independent samples t-test and a Mann-Whitney test were used, respectively, to compare these variables between the groups with a significance level set at 5%. Root canals prepared with either PTN or TFA systems were found to present similar untouched canal surface areas (P = 0.52) and hard-tissue debris accumulation (P = 0.39). Both systems produced a suboptimal and similar mechanical preparation of the mesial canals of mandibular molars and were not able to yield root canals completely free from packed hard-tissue debris.


Assuntos
Instrumentos Odontológicos , Materiais Restauradores do Canal Radicular/química , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Tomografia Computadorizada por Raios X/métodos , Desenho de Equipamento , Humanos , Dente Molar , Radiografia Dentária/métodos , Fatores de Risco , Amostragem , Estatísticas não Paramétricas , Extração Dentária
16.
J Appl Oral Sci ; 25(5): 551-558, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29069153

RESUMO

INTRODUCTION: Acute periradicular abscess is a condition characterized by the formation and propagation of pus in the periapical tissues and generally associated with debilitating pain. OBJECTIVE: The aim of this study was to compare the overall analgesic effectiveness of two combinations of opioid and non-opioid analgesics for acute periradicular abscess. MATERIAL AND METHODS: This study included 26 patients who sought emergency care in a Brazilian dental school. The patients were randomly divided into two groups: Co/Ac - oral prescription of codeine (30 mg) plus acetaminophen (500 mg), every 4 h, for 3 days or Tr/Ac - oral prescription of tramadol hydrochloride (37.5 mg) plus acetaminophen (500 mg) on the same schedule. Two factors were evaluated: (1) pain scores recorded by the patients in a pain diary 6, 12, 24, 48, and 72 h after treatment, using the Visual Analogue Scale; and (2) the occurrence of adverse effects. RESULTS: In both groups, there was a reduction in pain scores over time. For the Co/Ac group, there was a significant reduction in the scores 12, 24, 48, and 72 hours after treatment (P<0.05). In the Tr/Ac group, the scores significantly decreased over time from time point 6 h (P<0.05). Comparing the pain at each time point, the groups were not significantly different (P>0.05), i.e., both treatments were effective in controlling pain caused by APA; however, the combination of Tr/Ac caused more adverse reactions as two patients had to stop using the medication. CONCLUSION: This study suggests that, considering both analgesic efficacy and safety, the combination of codeine and acetaminophen is more effective to control moderate to severe pain from acute periradicular abscesses.


Assuntos
Acetaminofen/uso terapêutico , Dor Aguda/tratamento farmacológico , Analgésicos não Narcóticos/uso terapêutico , Analgésicos Opioides/uso terapêutico , Codeína/uso terapêutico , Abscesso Periapical/cirurgia , Tramadol/uso terapêutico , Doença Aguda , Adolescente , Adulto , Idoso , Analgesia/métodos , Método Duplo-Cego , Quimioterapia Combinada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Dor Pós-Operatória/tratamento farmacológico , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
17.
J. appl. oral sci ; 25(5): 551-558, Sept.-Oct. 2017. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-893649

RESUMO

Abstract Acute periradicular abscess is a condition characterized by the formation and propagation of pus in the periapical tissues and generally associated with debilitating pain. Objective: The aim of this study was to compare the overall analgesic effectiveness of two combinations of opioid and non-opioid analgesics for acute periradicular abscess. Material and Methods: This study included 26 patients who sought emergency care in a Brazilian dental school. The patients were randomly divided into two groups: Co/Ac - oral prescription of codeine (30 mg) plus acetaminophen (500 mg), every 4 h, for 3 days or Tr/Ac - oral prescription of tramadol hydrochloride (37.5 mg) plus acetaminophen (500 mg) on the same schedule. Two factors were evaluated: (1) pain scores recorded by the patients in a pain diary 6, 12, 24, 48, and 72 h after treatment, using the Visual Analogue Scale; and (2) the occurrence of adverse effects. Results: In both groups, there was a reduction in pain scores over time. For the Co/Ac group, there was a significant reduction in the scores 12, 24, 48, and 72 hours after treatment (P<0.05). In the Tr/Ac group, the scores significantly decreased over time from time point 6 h (P<0.05). Comparing the pain at each time point, the groups were not significantly different (P>0.05), i.e., both treatments were effective in controlling pain caused by APA; however, the combination of Tr/Ac caused more adverse reactions as two patients had to stop using the medication. Conclusion: This study suggests that, considering both analgesic efficacy and safety, the combination of codeine and acetaminophen is more effective to control moderate to severe pain from acute periradicular abscesses.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Adulto Jovem , Abscesso Periapical/cirurgia , Tramadol/uso terapêutico , Codeína/uso terapêutico , Analgésicos não Narcóticos/uso terapêutico , Dor Aguda/tratamento farmacológico , Analgésicos Opioides/uso terapêutico , Acetaminofen/uso terapêutico , Dor Pós-Operatória/tratamento farmacológico , Fatores de Tempo , Medição da Dor , Método Duplo-Cego , Doença Aguda , Reprodutibilidade dos Testes , Resultado do Tratamento , Quimioterapia Combinada , Analgesia/métodos
18.
J Endod ; 43(9): 1553-1558, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28735793

RESUMO

INTRODUCTION: The purpose of this study was to evaluate the development of dentinal microcracks after root canal preparation with Reciproc and ProTaper Universal systems using an in situ cadaver model by means of a micro-computed tomography (micro-CT) imaging system. METHODS: At autopsy, 8 maxillary bone blocks having at least the first and second premolar teeth (n = 16) were excised, scanned at a resolution of 13.18 µm, and randomly distributed into 2 groups (n = 8) according to the preparation protocol: Reciproc and ProTaper Universal systems. Root canals were prepared up to R25 and F2 instruments in the Reciproc and ProTaper Universal groups, respectively. After the preparation procedures, the specimens were scanned again, and the registered preoperative and postoperative cross-section images of the roots (n = 19,060) were screened to identify the presence of dentinal defects. RESULTS: In the Reciproc group, 9176 cross-section images were analyzed, and no crack was observed. In the ProTaper Universal group, 244 of 9884 cross-section slices (2.46%) had dentinal defects; however, all defects were already present in the corresponding preoperative images, indicating that no new microcrack was created after canal preparation. CONCLUSIONS: In situ root canal preparation of maxillary premolars with Reciproc and ProTaper Universal systems did not induce the formation of dentinal microcracks in a cadaver model as observed by micro-CT.


Assuntos
Dentina/diagnóstico por imagem , Dentina/lesões , Preparo de Canal Radicular/efeitos adversos , Microtomografia por Raio-X , Adulto , Cadáver , Humanos , Adulto Jovem
19.
J Endod ; 43(4): 619-622, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28216274

RESUMO

INTRODUCTION: The aim of the present study was to evaluate the percentage frequency of dentinal micro-cracks observed after root canal preparation with TRUShape and Self-Adjusting File (SAF) systems by means of micro-computed tomography imaging analysis. A conventional full-sequence rotary system (BioRace) and a single-file reciprocation system (Reciproc) were used as reference techniques for comparison because of their known assertive cutting efficiency. METHODS: Forty anatomically matched mandibular incisors were selected, scanned at a resolution of 14.25 µm, and assigned to 4 experimental groups (n = 10), according to the preparation protocol: TRUShape, SAF, BioRace, and Reciproc systems. After the experimental procedures, the specimens were scanned again, and the registered preoperative and postoperative cross-section images of the roots (n = 70,030) were screened to identify the presence of dentinal micro-cracks. RESULTS: Overall, dentinal defects were observed in 28,790 cross-section images (41.11%). In the TRUShape, SAF, BioRace, and Reciproc groups, dentinal micro-cracks were visualized in 56.47% (n = 9842), 42.38% (n = 7450), 32.90% (n = 5826), and 32.77% (n = 5672) of the slices, respectively. All dentinal defects observed in the postoperative data sets were already present in the corresponding preoperative images. CONCLUSIONS: None of the preparation systems induced the formation of new dentinal micro-cracks.


Assuntos
Radiografia Dentária , Preparo de Canal Radicular/efeitos adversos , Fraturas dos Dentes/etiologia , Microtomografia por Raio-X , Dentina/lesões , Humanos , Incisivo/lesões , Incisivo/cirurgia , Radiografia Dentária/métodos , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Fraturas dos Dentes/dietoterapia , Microtomografia por Raio-X/métodos
20.
Eur Endod J ; 2(1): 1-5, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-33403329

RESUMO

OBJECTIVE: This study sought to evaluate the effect of the penetration of an epoxy resin-based root canal sealer into dentin tubules on the force required to dislodge the root canal filling. METHODS: Sixty extracted human central incisors with single canals were decoronated, instrumented, and filled with gutta-percha and AH Plus sealer labeled with 0.1% rhodamine B dye. The roots were further sectioned horizontally at 3, 6, and 8 mm from the apex. The coronal surfaces of the resulting 180 slices were evaluated using confocal laser scanning microscopy to measure the amount of sealer that penetrated into the dentin tubules. To quantify the force required to dislocate the root filling material, the root fillings of the slices were subjected to a dislodgement resistance test (push-out). Spearman's rho correlation test was further used to test the correlation between the push-out bond strength and sealer penetration into the dentin tubules (P<0.05). RESULTS: No significant correlation was observed between sealer penetration into the dentin tubules and the force required to dislodge the root canal filling (P=0.626). CONCLUSION: Following the results of this study, the penetrating ability of the AH Plus sealer into dentin tubules has no correlation with the force required to dislodge the root canal filling.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...